12.2 System special address (HSW/HSX)
12.2.1 System data addresses
Address | Function | Description |
HSW0 | Language switch | Multiple language could be set in the project, HMI support maximum 8 languages. |
HSW1 | Beep frequency | Frequency range (0-4999) |
HSW2 | Beep volume | Volume range (0-80) |
HSW3 | Beep time | Unit: ms |
HSW4 | Beep switch | =0: Turn ON; =1: Turn OFF; |
HSW5 | Alarm lamp | =0: No alarm; =1: Alarm; |
HSW6~7 | The number of alarms | The number of alarm (it including released and not released) |
HSW8 | Number of not released alarms | The number of not released alarms |
HSW9 | Time out tip message | =0: Visible =1: Invisible |
HSW10 | System language | =0: Chinses; =1: English; |
HSW12 | Screen swicth | = 0: Only HSW control the screen switch = 1: Only HUW control the screen switch |
HSW13 | Designated screen switch | The screen will switch to designated screen |
HSW24 | Reboot HMI | =1: Reboot |
HSW28 | Local time: year | Range: 0~9999 |
HSW29 | Local time: month | Range: 1~12 |
HSW30 | Local time: day | Range: 1~31 |
HSW31 | Local time: hour | Range: 0~23 |
HSW32 | Local time: minute | Range: 0~59 |
HSW33 | Local time: second | Range: 0~59 |
HSW34 | Local time: week | On simulator: =0: Sunday; =1: Monday; =2: Tuesday; =3: Wednesday; =4: Thursday; =5: Friday; =6: Saturday; On HMI: =0: Sunday; =1: Saturday; =2: Monday; =3: Tuesday; =4: Wednesday; =5: Thursday; =6: Friday, |
HSW134 | Script reading | =0: Read from HMI cache =1: Read from PLC |
HSW135 | Confirm installment password | Confirm button for installment password |
HSW151 | Installment due | Number of days to installment due |
HSW185~200 | Installment password | Enter installment password |
HSW242 | Prompt result of recipe operation | =1: Download, start =3: Download, files don’t exist =4: Download, members don’t exist =5: Download, groups don’t exist =6: Download, success =7: Upload, start =8: Upload, execute error =9: Upload, files don’t exist =10: Upload, members don’t exist =11: Upload, groups don’t exist =12: Upload, success =13: Insert, start =14: Insert, execute error =15: Insert, files don’t exist =16: Insert, members don’t exist =17: Insert, groups don’t exist =18: Insert, success =19: Delete, start =20: Delete, execute error =21: Delete, files don’t exist =22: Delete, members don’t exist =23: Delete, groups don’t exist =24: Delete, success =25: Delete and sort, start =26: Delete and sort, execute error =27: Delete and sort, files don't exist =28: Delete and sort, members don't exist =29: Delete and sort, groups don't exist =30: Delete and sort, success |
HSW243 | Prompt result of recipe index | =31: Recipe index, start =32: Recipe index, execute error =33: Recipe index, files don’t exist =34: Recipe index, members don’t exist =35: Recipe index, groups don’t exist =36: Recipe index, success |
HSW521 | Delete graph and alarm record | =0: No operation =1: HSX521.0 = 1, delete all records; =2: HSX521.1 = 1, delete all trend graph; =4: HSX521.2 = 1, delete all alarms; =16: HSX521.4 = 1, delete history XY plot; =32: HSX521.5 = 1, delete data records in SD card or flash dish;(Please make a setting which is saved to flash disk or SD card in project setting); =64: HSX521.6 = 1, delete alarms records in SD card or flash dish; (Please make a setting which is saved to flash disk or SD card in project setting). |
HSW522 | Copy and paste the alarm/data files in flash to the USB flash disk | =0: No operation =1: HSX522.0 = 1, copy all record =2: HSX522.2 = 1, copy history XY trend graph =8: HSX522.3 = 1, copy alarm record =32: HSX522.5 = 1, copy recipe |
HSW523 | Copy and paste the alarm/data files in flash to the SD card | =0: No operation =1: HSX523.0 = 1, copy all record =4: HSX523.2 = 1, copy history XY trend graph =8: HSX523.3 = 1, copy alarm record |
HSW524 | Copy and paste the alarm/data files in SD card to the USB flash disk | =0: no operation =4: HSX524.2 = 1, copy history XY trend graph =8: HSX524.3 = 1, copy alarm record =16: HSX524.4 = 1, copy history alarm record =32: HSX524.5 = 1, copy data record |
HSW525 | Copy and paste the alarm/data files in USB flash disk to SD card | =0: no operation =4: HSX525.2=1, copy history XY trend graph =8: HSX525.3 = 1, copy alarm record =16: HSX525.4=1, copy history alarm record =32: HSX525.5= 1, copy data record |
HSW526 | Delete file list | =0: no operation =1: HSX526.0 = 1, delete designated file =2: HSX526.1 = 1, delete all files |
HSW527 | Eject USB flash disk/SD card | =0: No operation =1: Eject USB flash disk =2: Eject SD card |
HSW528 | The state of USB flash disk | =1: USB flash disk is detected =2: Ejecting USB flash disk, please waiting… =3: USB flash disk ejected |
HSW529 | The state of SD card | =1:SD card is detected =2: Ejecting SD card, please waiting… =3: SD card ejected |
HSW550~849 | Communication control | For communication control and communication lamp (please refer to communication control sector for detailed) |
HSW850 | Network state | Display network state =0: Disconnected; =1: only connected LAN, so APP can’t access HMI; =2: Connected WECON Cloud, APP and web could access HMI; |
HSW855 | Backlight Control | HSX855.0 = 1: turn on the backlight and reset automatically after being triggered; HSX855.1= 1: turn off the backlight and reset automatically after being triggered; |
HSW856 | Close the sub-screen or indirect screen when switching screen control (when the former screen is switched to the current screen) | =0: close the sub-screen, including the indirect screen; =1: not to close. |
HSW857 | Permission in remote access (web page, mobile APP, cloud platform, etc.) | =0: users could switch the screen, control the switch and update data in remote access; =1: users could only control function switch, i.e., could only switch the screen, view data and switch state, but could not operate or update them. |
HSW881 | Storage of Record files | It is used for controlling saving alarm/data record files to U disk / SD card. = 0: Save to storage; = 1: Don't save to storage; |
HSW882 | Storage device status | HDX882.0=0 USB flash doesn’t execute storage or storage finished; HDX882.0=1 USB flash is reading data, don’t remove USB flash; HDX882.1=0 SD card doesn’t execute storage or storage finished; HDX882.1=1 SD card is reading data, don’t remove SD card; |
HSW884 | Into setup screen | = 0: Do not into setup screen = 1: Into setup screen |
HSW885 | When the control object hides the address read failure (communication failure), set the display mode of the object | = 0: displayed by object setting. =1: control address read failure, the address control of all objects is hidden, not displayed. =2: control address read failure, the address control of all objects is displayed, not hidden. |
HSW893 | User Restriction Control Address like the special address HUW1000 feature, refer to "User Rights " | =1: User Log in =2: Change User password =3: User Log out =4: New user =5: Delete user =6: Add user rights =8: Add Hide features =9: Delete Profile =10: Export Profile =11: Import profile =12: Export log file =13: Delete log file |
HSW900 | Quick update frequency settings for objects | Valid when the object is enabled for [quick update]. Default: 5. Range: 1 (fastest) ~ 50 (slowest) |
HSW920 | Maximum periods (Static mode) | Numeric Input/ Display (range: 0-12) |
HSW921 ~ 924 | Admin key (Static mode) | Character Input/ Display (length: 8) |
HSW925 ~ 928 | 1st period key (Static mode) | Character Input/ Display (length: 8) |
HSW929 ~ 933 | 1st expiry time (Static mode) | Numeric Input/ Display (YYYYMMDDHHMM) |
HSW935 ~ 938 | 2nd period key (Static mode) | Character Input/ Display (length: 8) |
HSW939 ~ 943 | 2nd expiry time (Static mode) | Numeric Input/ Display (YYYYMMDDHHMM) |
HSW945 ~ 948 | 3rd period key (Static mode) | Character Input/ Display (length: 8) |
HSW949 ~ 953 | 3rd expiry time (Static mode) | Numeric Input/ Display (YYYYMMDDHHMM) |
HSW955 ~ 958 | 4th period key (Static mode) | Character Input/ Display (length: 8) |
HSW959 ~ 963 | 4th expiry time (Static mode) | Numeric Input/ Display (YYYYMMDDHHMM) |
HSW965 ~ 968 | 5th period key (Static mode) | Character Input/ Display (length: 8) |
HSW969 ~ 973 | 5th expiry time (Static mode) | Numeric Input/ Display (YYYYMMDDHHMM) |
HSW975 ~ 978 | 6th period key (Static mode) | Character Input/ Display (length: 8) |
HSW979 ~ 983 | 6th expiry time (Static mode) | Numeric Input/ Display (YYYYMMDDHHMM) |
HSW985 ~ 988 | 7th period key (Static mode) | Character Input/ Display (length: 8) |
HSW989 ~ 993 | 7th expiry time (Static mode) | Numeric Input/ Display (YYYYMMDDHHMM) |
HSW995 ~ 998 | 8th period key (Static mode) | Character Input/ Display (length: 8) |
HSW999 ~ 1003 | 8th expiry time (Static mode) | Numeric Input/ Display (YYYYMMDDHHMM) |
HSW1005 ~1008 | 9th period key (Static mode) | Character Input/ Display (length: 8) |
HSW1009 ~ 1013 | 9th expiry time (Static mode) | Numeric Input/ Display (YYYYMMDDHHMM) |
HSW1015 ~1018 | 10th period key (Static mode) | Character Input/ Display (length: 8) |
HSW1019 ~ 1023 | 10th expiry time (Static mode) | Numeric Input/ Display (YYYYMMDDHHMM) |
HSW1025 ~1028 | 11th period key (Static mode) | Character Input/ Display (length: 8) |
HSW1029 ~ 1033 | 11th expiry time (Static mode) | Numeric Input/ Display (YYYYMMDDHHMM) |
HSW1035 ~1038 | 12th period key (Static mode) | Character Input/ Display (length: 8) |
HSW1039 ~ 1043 | 12th expiry time (Static mode) | Numeric Input/ Display (YYYYMMDDHHMM) |
HSW1046 | Current period (Static mode) | Current period (Range 1-13) |
HSW1047 | Save settings (Static mode) | HSX1047.0=1: Save static installment information HSX1047.1=1: Write installment information to registers |
HSW1070 | The time interval (seconds) since the last time the screen was clicked | Shows how long the current screen has not been clicked, using a decimal unsigned double word (Numeric Input/ Display). Note: This register is cleared to zero regardless of which user clicks on the screen. |
HSW1086 | Address mapping polling cycle, unit: ms | Address mapping polling cycle, effective range: 40~1000ms, default: 300ms. |
HSW1087 | Write interval in address mapping | Address length setting, triggers a write operation when N addresses change. The effective range: 0-5, and default is 2. When N more than 5, it becomes 5. |
HSW1088 | Write interval in scripts | Address length setting, triggers a write operation when N addresses change. The effective range: 0-5, and default is 2. When N more than 5, it becomes 5. |
HSW1089 | Interval in read through | Address length setting, triggers a write operation when N addresses change. The effective range: 0-5, and default is 2. When N more than 5, it becomes 5. |
HSW1140 | Trigger objects security function | =0, Disable =1, Enable |
HSW1141 | Each level independent | =0, No, high-level passwords can unlock low-level =1, Yes, high-level passwords cannot unlock low-level |
HSW1142 | Initialization level | Initialization level while HMI running |
HSW1144 | Password for Level 1 | Maximum character length 8 allowed in password (numbers, letters (case sensitive)). |
HSW1148 | Password for Level 2 | Maximum character length 8 allowed in password (numbers, letters (case sensitive)). |
HSW1152 | Password for Level 3 | Maximum character length 8 allowed in password (numbers, letters (case sensitive)). |
HSW1156 | Password for Level 4 | Maximum character length 8 allowed in password (numbers, letters (case sensitive)). |
HSW1160 | Password for Level 5 | Maximum character length 8 allowed in password (numbers, letters (case sensitive)). |
HSW1164 | Password for Level 6 | Maximum character length 8 allowed in password (numbers, letters (case sensitive)). |
HSW1168 | Password for Level 7 | Maximum character length 8 allowed in password (numbers, letters (case sensitive)). |
HSW1172 | Password for Level 8 | Maximum character length 8 allowed in password (numbers, letters (case sensitive)). |
HSW1176 | Password for Level 9 | Maximum character length 8 allowed in password (numbers, letters (case sensitive)). |
HSW1180 | Password for Level 10 | Maximum character length 8 allowed in password (numbers, letters (case sensitive)). |
HSW1184 | Password for Level 11 | Maximum character length 8 allowed in password (numbers, letters (case sensitive)). |
HSW1188 | Password for Level 12 | Maximum character length 8 allowed in password (numbers, letters (case sensitive)). |
HSW1192 | Save and undo settings | =1, Save, save the data of HSW1140, HSW1141, HSW1142, HSW1144-HSW1188 to a file, the data will not change after restart (note: the file will be deleted if download a new project) =2,Undo, undo modification of HSW1140、HSW1141、HSW1142、HSW1144-HSW1188 (note: If click save, the operation is invalid) |
HSW10000~19999 | Power OFF protection | |
HSW10035 | The Ethernet parameter is only editable, when the settings are programmed in HMI software. | Local IP address high endian 1 |
HSW10036 | The Ethernet parameter is only editable, when the settings are programmed in HMI software. | Local IP address high endian 2 |
HSW10037 | The Ethernet parameter is only editable, when the settings are programmed in HMI software. | Local IP address high endian 3 |
HSW10038 | The Ethernet parameter is only editable, when the settings are programmed in HMI software. | Local IP address high endian 4 |
HSW10039 | The Ethernet parameter is only editable, when the settings are programmed in HMI software. | Local mask IP address high endian 1 |
HSW10040 | The Ethernet parameter is only editable, when the settings are programmed in HMI software. | Local mask IP address high endian 2 |
HSW10041 | The Ethernet parameter is only editable, when the settings are programmed in HMI software. | Local mask IP address high endian 3 |
HSW10042 | The Ethernet parameter is only editable, when the settings are programmed in HMI software. | Local mask IP address high endian 4 |
HSW10043 | The Ethernet parameter is only editable, when the settings are programmed in HMI software. | Local gateway high endian 1 |
HSW10044 | The Ethernet parameter is only editable, when the settings are programmed in HMI software. | Local gateway high endian 2 |
HSW10045 | The Ethernet parameter is only editable, when the settings are programmed in HMI software. | Local gateway high endian 3 |
HSW10046 | The Ethernet parameter is only editable, when the settings are programmed in HMI software. | Local gateway high endian 4 |
HSW10047 | The Ethernet parameter is only editable, when the settings are programmed in HMI software. | Local port address |
HSW10048 | Displays the MAC code of the current network card (Hexadecimal display) | Local MAC code high word 1 |
HSW10049 | Displays the MAC code of the current network card (Hexadecimal display) | Local MAC code high word 2 |
HSW10050 | Displays the MAC code of the current network card (Hexadecimal display) | Local MAC code high word 3 |
HSW10051 | Displays the MAC code of the current network card (Hexadecimal display) | Local MAC code high word 4 |
HSW10052 | Displays the MAC code of the current network card (Hexadecimal display) | Local MAC code high word 5 |
HSW10053 | Displays the MAC code of the current network card (Hexadecimal display) | Local MAC code high word 6 |
HSW10461~10493 | Remote access password | 8-character remote access password |
HSW10494~10558 | Machine ID (Read only) | Machine ID for remote access (read only 64-bit) |
HSW10576 | Save dynamic installment settings | HSX10576.0=1: save settings |
HSW10577 | Control address for installment | HSX10577.0=0: disable dynamic installment HSX10577.0=1: enable dynamic installment HSX10577.1=0: disable static installment HSX10577.1=1: enable static installment |
HSW10578-10583 | Character Input/ Display (length: 6) | Password |
HSW10584-10586 | Numeric Input/ Display (YYYYMMDD) | Expiry time |
HSW10587-10589 | Numeric Input/ Display (YYYYMMDD) | Expiry time (set in program) |
HSW10590 | Background light time | Set the light time for background =0: lit all the time; Others: light time (unit: S) |
HSW10591 | Backlight brightness adjustment | Backlight brightness range: 1 (darkest) ~ 100 (brightest) |
HSW10603 | Set the printer to print orientation | Set the print direction: =1: Forward printing =2: Reverse print Other: Forward print |
HSW10604 | Print dot type | =1: 8 dot matrix type; =2: 24 dot matrix type; Other: 8 dot matrix type |
HSW10605 | Printer print width | Set the width of the printer to print (in pixels), such as HSW10605 = 394: The printer supports images with a print width of 394 pixels |
HSW10606 | Printer instruction type | =1: Graphic print type =2: Dot density printing type |
HSW10607 | Cut function | =1: Enable the cut function =2: Disable cutting function |
HSW10608 | Print the alignment of the text | =1: Left justified =2: Center alignment =3: Right justified |
12.2.2 Serial port communication configuration
Port | Address | Function | Description |
COM1 | HSW010061 | Communication | =0: RS232 =1: RS485 =2: RS422 |
HSW010062 | Baud rate | =0: 1200 =1: 2400 =2: 4800 =3: 9600 =4: 19200 =5: 38400 =6: 57600 =7: 115200 =8: 230400 | |
HSW010063 | Data bit | =7: 7 bit =8: 8 bit | |
HSW010064 | Stop bit | =1: 1 bit =2: 2 bit | |
HSW010065 | Check bit | =0: None =1: ODD =2: EVEN | |
HSW010066 | Wait timeout | ||
HSW010067 | Read timeout | ||
HSW010068 | Retry time | ||
HSW010069 | Retry timeout | ||
HSW010070 | HMI station number | ||
HSW010071 | PLC station number | ||
COM2 | HSW010072 | Communication | =0: RS232 =1: RS485 |
HSW010073 | Baud rate | =0: 1200 =1: 2400 =2: 4800 =3: 9600 =4: 19200 =5: 38400 =6: 57600 =7: 115200 =8: 230400 | |
HSW010074 | Data bit | =7: 7 bit =8: 8 bit | |
HSW010075 | Stop bit | =1: 1 bit =2: 2 bit | |
HSW010076 | Check bit | =0: None =1: ODD =2: EVEN | |
HSW010077 | Wait timeout | ||
HSW010078 | Read timeout | ||
HSW010079 | Retry time | ||
HSW010080 | Retry timeout | ||
HSW010081 | HMI station number | ||
HSW010082 | PLC station number | ||
COM3 | HSW010083 | Communication | =0: RS232 =1: RS485 =2: RS422 |
HSW010084 | Baud rate | =0: 1200 =1: 2400 =2: 4800 =3: 9600 =4: 19200 =5: 38400 =6: 57600 =7: 115200 =8: 230400 | |
HSW010085 | Data bit | =7: 7 bit =8: 8 bit | |
HSW010086 | Stop bit | =1: 1 bit =2: 2 bit | |
HSW010087 | Check bit | =0: None =1: ODD =2: EVEN | |
HSW010088 | Wait timeout | ||
HSW010089 | Read timeout | ||
HSW010090 | Retry time | ||
HSW010091 | Retry timeout | ||
HSW010092 | HMI station number | ||
HSW010093 | PLC station number | ||
COM1-2 | HSW010094 | Communication | =0: RS232 =1: RS485 =2: RS422 |
HSW010095 | Baud rate | =0: 1200 =1: 2400 =2: 4800 =3: 9600 =4: 19200 =5: 38400 =6: 57600 =7: 115200 =8: 230400 | |
HSW010096 | Data bit | =7: 7 bit =8: 8 bit | |
HSW010097 | Stop bit | =1: 1 bit =2: 2 bit | |
HSW010098 | Check bit | =0: None =1: ODD =2: EVEN | |
HSW010099 | Wait timeout | ||
HSW010100 | Read timeout | ||
HSW010101 | Retry time | ||
HSW010102 | Retry timeout | ||
HSW010103 | HMI station number | ||
HSW010104 | PLC station number | ||
COM2-2 | HSW010105 | Communication | =0: RS232 =1: RS485 =2: RS422 |
HSW010106 | Baud rate | =0: 1200 =1: 2400 =2: 4800 =3: 9600 =4: 19200 =5: 38400 =6: 57600 =7: 115200 =8: 230400 | |
HSW010107 | Data bit | =7: 7 bit =8: 8 bit | |
HSW010108 | Stop bit | =1: 1 bit =2: 2 bit | |
HSW010109 | Check bit | =0: None =1: ODD =2: EVEN | |
HSW010110 | Wait timeout | ||
HSW010111 | Read timeout | ||
HSW010112 | Retry time | ||
HSW010113 | Retry timeout | ||
HSW010114 | HMI station number | ||
HSW010115 | PLC station number |
12.2.3 Ethernet communication configuration
No. | Address | Function | Description |
1 | HSW11004 | Ethernet parameter configuration for communication number 1 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI. | IP address high endian 1 |
HSW11005 | IP address high endian 2 | ||
HSW11006 | IP address high endian 3 | ||
HSW11007 | IP address high endian 4 | ||
HSW11008 | Port number | ||
HSW11009 | =2 TCP; =3 UDP | ||
HSW11010 | Reserved | ||
2 | HSW11011 | Ethernet parameter configuration for communication number 2 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI. | IP address high endian 1 |
HSW11012 | IP address high endian 2 | ||
HSW11013 | IP address high endian 3 | ||
HSW11014 | IP address high endian 4 | ||
HSW11015 | Port number | ||
HSW11016 | =2 TCP; =3 UDP | ||
HSW11017 | Reserved | ||
… | … | … | |
32 | HSW11221 | Ethernet parameter configuration for communication number 32 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI. | IP address high endian 1 |
HSW11222 | IP address high endian 2 | ||
HSW11223 | IP address high endian 3 | ||
HSW11224 | IP address high endian 4 | ||
HSW11225 | Port number | ||
HSW11226 | =2 TCP; =3 UDP | ||
HSW11227 | Reserved |
12.2.4 Communication control
Default setting, ON=0; OFF=1. normal=0; error=1
No. | Station No. | Control bit | Communication lamp | |
1 | ||||
0~15 | HSX550.0~550.15 | HSX558.0~558.15 | ||
16~31 | HSX551.0~551.15 | HSX559.0~559.15 | ||
32~47 | HSX552.0~552.15 | HSX560.0~560.15 | ||
48~63 | HSX553.0~553.15 | HSX561.0~561.15 | ||
2 | ||||
0~15 | HSX566.0~566.15 | HSX574.0~574.15 | ||
16~31 | HSX567.0~567.15 | HSX575.0~575.15 | ||
32~47 | HSX568.0~568.15 | HSX576.0~576.15 | ||
48~63 | HSX569.0~569.15 | HSX577.0~577.15 | ||
3 | ||||
0~15 | HSX582.0~582.15 | HSX590.0~590.15 | ||
16~31 | HSX583.0~583.15 | HSX591.0~591.15 | ||
32~47 | HSX584.0~584.15 | HSX592.0~592.15 | ||
48~63 | HSX585.0~585.15 | HSX593.0~593.15 | ||
4 | ||||
0~15 | HSX598.0~598.15 | HSX606.0~606.15 | ||
16~31 | HSX599.0~599.15 | HSX607.0~607.15 | ||
32~47 | HSX600.0~600.15 | HSX608.0~608.15 | ||
48~63 | HSX601.0~601.15 | HSX609.0~609.15 | ||
5 | ||||
0~15 | HSX614.0~614.15 | HSX622.0~622.15 | ||
16~31 | HSX615.0~615.15 | HSX623.0~623.15 | ||
32~47 | HSX616.0~616.15 | HSX624.0~624.15 | ||
48~63 | HSX617.0~617.15 | HSX625.0~625.15 | ||
6 | ||||
0~15 | HSX630.0~630.15 | HSX638.0~638.15 | ||
16~31 | HSX631.0~631.15 | HSX639.0~639.15 | ||
32~47 | HSX632.0~632.15 | HSX640.0~640.15 | ||
48~63 | HSX633.0~633.15 | HSX641.0~641.15 | ||
7 | ||||
0~15 | HSX646.0~646.15 | HSX654.0~654.15 | ||
16~31 | HSX647.0~647.15 | HSX655.0~655.15 | ||
32~47 | HSX648.0~648.15 | HSX656.0~656.15 | ||
48~63 | HSX649.0~649.15 | HSX657.0~657.15 | ||
8 | ||||
0~15 | HSX662.0~662.15 | HSX670.0~670.15 | ||
16~31 | HSX663.0~663.15 | HSX671.0~671.15 | ||
32~47 | HSX664.0~664.15 | HSX672.0~672.15 | ||
48~63 | HSX665.0~665.15 | HSX673.0~673.15 | ||
9 | ||||
0~15 | HSX678.0~678.15 | HSX686.0~686.15 | ||
16~31 | HSX679.0~679.15 | HSX687.0~687.15 | ||
32~47 | HSX680.0~680.15 | HSX688.0~688.15 | ||
48~63 | HSX681.0~681.15 | HSX689.0~689.15 | ||
10 | ||||
0~15 | HSX694.0~694.15 | HSX702.0~702.15 | ||
16~31 | HSX695.0~695.15 | HSX703.0~703.15 | ||
32~47 | HSX696.0~696.15 | HSX704.0~704.15 | ||
48~63 | HSX697.0~697.15 | HSX705.0~705.15 | ||
11 | ||||
0~15 | HSX710.0~710.15 | HSX718.0~718.15 | ||
16~31 | HSX711.0~711.15 | HSX719.0~719.15 | ||
32~47 | HSX712.0~712.15 | HSX720.0~720.15 | ||
48~63 | HSX713.0~713.15 | HSX721.0~721.15 | ||
12 | ||||
0~15 | HSX726.0~726.15 | HSX734.0~734.15 | ||
16~31 | HSX727.0~727.15 | HSX735.0~735.15 | ||
32~47 | HSX728.0~728.15 | HSX736.0~736.15 | ||
48~63 | HSX729.0~729.15 | HSX737.0~737.15 | ||
13 | ||||
0~15 | HSX742.0~742.15 | HSX750.0~750.15 | ||
16~31 | HSX743.0~743.15 | HSX751.0~751.15 | ||
32~47 | HSX744.0~744.15 | HSX752.0~752.15 | ||
48~63 | HSX745.0~745.15 | HSX753.0~753.15 | ||
14 | ||||
0~15 | HSX758.0~758.15 | HSX766.0~766.15 | ||
16~31 | HSX759.0~759.15 | HSX767.0~767.15 | ||
32~47 | HSX760.0~760.15 | HSX768.0~768.15 | ||
48~63 | HSX761.0~761.15 | HSX769.0~769.15 | ||
15 | ||||
0~15 | HSX774.0~774.15 | HSX782.0~782.15 | ||
16~31 | HSX775.0~775.15 | HSX783.0~783.15 | ||
32~47 | HSX776.0~776.15 | HSX784.0~784.15 | ||
48~63 | HSX777.0~777.15 | HSX785.0~785.15 | ||
16 | ||||
0~15 | HSX790.0~790.15 | HSX798.0~798.15 | ||
16~31 | HSX791.0~791.15 | HSX799.0~799.15 | ||
32~47 | HSX792.0~792.15 | HSX800.0~800.15 | ||
48~63 | HSX793.0~793.15 | HSX801.0~801.15 |