12.1 System special address (HUW/HUX)
Last updated
Last updated
HUW register is used for system special:
1) The range of word address is: HUW0 - HUW50000.
2) The range of bit address is: HUX0.0-HUX50000.15.
Note: HUW/HUX belongs to the system special register (Operation for single terminal), so in the process of use, please refer to the system special register table. Do not use the address not listed in the table.
Address
Description
Function
HUW0
Screen switch
A single terminal controls the screen switching, and all terminals do not affect each other.
HUW110~129
Addresses of the built-in keyboard
Reserved
HUW135
Addresses of the built-in keyboard
Input method: first input
HUW136~199
Addresses of the built-in keyboard
Reserved
HUW200~699
Addresses of the built-in keyboard
Input method cache length
HUW700~749
Addresses of the built-in keyboard
Minimum value of the input method
HUW750~799
Addresses of the built-in keyboard
Maximum value of the input method
HUW800
Addresses of the built-in keyboard
Input method: case switching
HUW801~900
Addresses of the built-in keyboard
Input method format cache length
HUW1000
Addresses of user permission
OK (Sign in)
HUW1001
Addresses of user permission
Result of operation
HUW1002~1005
Addresses of user permission
Old password
HUW1006~1009
Addresses of user permission
New password
HUW1010~1013
Addresses of user permission
Confirm password
HUW1014~1029
Addresses of user permission
New user name
HUW1030~1157
Addresses of user permission
States information of user permission
HUW1158~1335
Addresses of user permission
User name (For drop-down list object)
HUW1336~1345
Addresses of user permission
User name description or note
HUW1347
Addresses of user permission
Hidden
HUW1348
Addresses of user permission
Permission settings
HUW1349
Addresses of user permission
Current user name
HUW1382
User sign in way
0: In the drop-down list, select the user name from drop-down list object for signing in;
1: Enter the user name in Character Input/Display object for signing in (HUW1014)
HUW1400
Time interval from last operation
Shows how long the touch screen has not been clicked, in seconds. 32-bit unsigned integer
Note: Clicking by different users will only clear the corresponding register of the currently operating terminal, and the registers on other terminals (such as mobile phones, computers) will not be cleared.
HUW1402
Keyboard note
It saves the text information of the keyboard notes when clicking object (HUW1402-HUW1433)
HUW1436
Current Level
Indicate current object security level