11.9 Mitsubishi FX5U Ethernet

Mitsubishi FX5U series PLC

HMI settings

Items

Settings

Note

Protocol

Mitsubishi FX5U

Connection

Ethernet

Port No.

5002

PLC station No.

0

Address list

Type

Device registers

HMI registers

Format

Range

Note

Bit

X

X

X o

0~303237

Y

Y

Y o

0~303237

M

M

M d

0~99999

B

B

B h

0~7FFF

F

F

F d

0~32767

SB

SB

SB h

0~7FFF

TS

TS

TS d

0~1023

TC

TC

TC d

0~1023

STS

STS

STS d

0~1023

STC

STC

STS d

0~1023

CS

CS

CS d

0~1023

CC

CC

CC d

0~1023

SM

SM

SM d

0~9999

L

L

L d

0~32767

S

S

S d

0~4095

Word

W

W

W h

0~3FF

TN

TN

TN d

0~1023

STN

STN

STN d

0~1023

CN

CN

CN d

0~1023

R

R

R d

0~32767

SW

SW

SW h

0~7FFF

Z

Z

Z d

0~23

D

D

D d

0~7999

SD

SD

SD d

0~11999

PLC settings (GX Works 3)

1) Find the [Ethernet port] in the navigation area.

2) Select [Own Node Settings] in the [Setting Item List].

3) IP address input as below, and subnet mas and default gateway is indeed. Keep the rest item as default, then click “check” and “apply”.

4) Switch to the [On line data operation] interface as below, check the item and click [Execute] to download.

Communication cable