11.1Allen-Bradley FreeTag Ethernet/IP (CompactLogix)
Last updated
Last updated
Allen-Brandly CompactLogix
HMI settings
Items | Settings | Note |
Protocol | Allen-Brandley FreeTag Ethernet/IP (CompactLogix) | |
Connection | Ethernet | |
Port No. | 44818 |
PLC Setting
1) Create new tags
2) Export Tag data to CSV file. ([Tools] » [Export] » [Tags and Logic Comments])
3) Import labels, please open [Communication] window and click [Import label];
4) Select csv file, all tags will be displayed as belows;
✎Note:
The separator character in CSV file needs to be a comma [,] otherwise the file would be invalid.
The directory of changing system settings: [Control Panel] -> [Date, Time, Language, and Regional Options] -> [Change the format of numbers, dates, and times]-> [Customize]-> [List separator]. Please select [,] and export CSV file after setting.
Communication settings in HMI
1) Enable HMI Ethernet in [Project Settings];
2) Set PLC IP in [Device IP] settings;
Cable wiring