Supported Series: Siemens S7-300 series PLC
HMI Setting
Address list
Communication settings
9) Enable HMI Ethernet in [Project Settings];
10) Set PLC IP in [Device IP] settings;
PLC IP Address: PLC IP
PLC pot No.: 102(fixed)
Network: TCP_Client_2N (fixed)
Wait timeout: depend on actual network situation (more than 1500 ms)
Communication cable
Items
Settings
Note
Protocol
Siemens S7-300 Ethernet
Connection
Ethernet
Port No.
102
PLC station No.
2
Need to be same as the PLC setting
Type
Device register
HMI register
Format
Range
Note
Bit
I
I
I ddddd.o
0.0~99999.7
Q
Q
Q ddddd.o
0.0~99999.7
M
M
M ddddd.o
0.0~99999.7
DB0.DB~DB99.DB
DBxDBD
DBxDB nndddd.o
0.0~99999999.7
nn: block number;
dddd: address;
Word
I
IW
IW ddddd
0~99999
Q
QW
QW ddddd
0~99999
M
MB
MB ddddd
0~99999
MW
MW ddddd
0~99999
MW0=MB(0~1)
MW2=MB(2~3)
Address value is a multiple of 2
MD
MD ddddd
0~99999
MD0=MB(0~3)
MD4=MB(4~7)
Address value is a multiple of 4
DB0.DB~DB99.DB
DBxDBB
DBxDBB nndddd
0~99999999
nn: block number;
dddd: address
DBxDBW
DBxDBW nndddd
0~99999999
DBxDBD
DBxDBD nndddd
0~99999999