11.5 Hitachi EHV Series (Ethernet)

Supported series: Hitachi EHV series

HMI settings

Items

Settings

Note

Protocol

Hitachi EHV series

Connection

Ethernet

Port No.

3004~3007

Address list

Type

Register

Range

Format

Note

Bit

T

0 - 2545

T DDDD

M

0 - 7FFF.f (Hex)

M HHHH.h

X

0 – FFFF.f (Hex)

X H1H2H3H4.h

H1H2H3H4 Module main number

H1: Remote number

H2: Unit number

H3: Slot number

H4: Word number of Module

H Sub number of Module

For example: X21.3

Slot number 2

Word number of module is 1

Bit number of module is 3

Remote number and unit number are 0

Y

0 – FFFF.f (Hex)

Y H1H2H3H4.h

R

0 – FF.f (Hex)

R HH.h

L

0 - 73FF.f (Hex)

L HHHH.h

Word

WM

0 - 7FFF (Hex)

WM HHHH

WX

0 – FFFF (Hex)

WX H1H2H3H4

H1H2H3H4 Module main number

H1: Remote number

H2: Unit number

H3: Slot number

H4: Word number of module

For example: WX21

Word number of module is 1

Slot number is 2

Remote number and unit number are 0

WY

0 – FFFF (Hex)

WY H1H2H3H4

WR

0 – FFFF (Hex)

WR HHHH

WL

0 - 73FF (Hex)

WL HHHH

TC

0 - 2559

TC DDDD

Communication settings in HMI

1) Enable HMI Ethernet in [Project Settings];

2) Set PLC IP in [Device IP] settings;

PLC configuration

1) Connect with PLC, select [Online mode];

2) Set IP address, it is the same LAN parameters with HMI;

3) Save PLC communication parameter, and restart PLC

PLC monitor mode

1) Connect with PLC and choose to “online” mode

2) Open I/O monitor sheet 1

3) During monitoring bit address, 1 pts should be selected; during monitoring word address, 16 pts should be selected

4) Enter the register address, click OK to view the value of the register.

Note:

1) Both word registers and bit registers support even continuous read/write functions;

2) The range of registers is based on the specific PLC type;